Required assembly dimensions of hardware
Version 1 / 2: Height and distance between full-in/full-out position of glass
A [mm]: distance covered by glass between full-in and full-out position
H [mm]: visible glass height
L [mm]: total glass height
AP [mm]: worktop thickness
OT [mm]: top dead center (top limit switch actuated)
Note: OT can range from 20 mm to 62.5 mm depending on where operating panel is positioned.
A = H + AP + 22 mm
L = H + AP + OT
Example:
H = 450 mm. Worktop thickness is 19 mm and OT is 20 mm.
-> A = 450 mm + 19 mm + 22 mm
-> A = 491 mm.
As a result hardware article no 449.2200.000 must be selected (distance covered by glass between full-in and full-out position ranges from 480 mm to 565 mm).
Resulting glass height is:
-> L = 450 mm + 19 mm + 20 mm
-> L = 489 mm
Self-closing cover strip
Cover strip supplied in L= 1,500 mm, to be shortened by customer.
- Locking unit of cover strip
Position locking units next to glass clamp profile.
Minimum distance between locking units: Version 1 = 805 mm / Version 2 = 1,060 mm.
Version 1:
Version 2:
Horizontal adjustment of front glass
Tilting of front glass
Cabling of motor and limit switch
Adjustment of front glass position
Assembly position of front suspensions
Retractable top glass
In combination with a top service plate, a gap of > 12 mm must be provided between the upper edge of the front glass and the lower edge of the top service plate.
- Geometry and glass cut-out
* min. 75 mm when combining front strut and self-closing cover strip.